- constant signal;
- sinusoidal signal;
- triangular signal;
- rectangular signal;
- arbitrary signal.
The stand allows doing the following laboratory works:
- To plot up to 21 measuring channels on the same axis with individual setup of vertical parameters for each channel and common setup of horizontal parameters for all channels.
- To compare measured signals.
- To make real time mathematical calculations of measured parameters and display them.
- To display function, momentary and average signal value.
- To measure signal frequency.
- To plot Lissajous figures for any of the two measuring channels.
- To analyze spectrum of any of the measuring channels used.
- To measure the signal frequency of any signal used.
- To calculate active and reactive constituents of power, total power, power coefficient.
- To save data array from buffer for further analysis.
- To export oscillograms to graph formats JPG, BMB.
- To set DAC values while forming constant signal, sinusoidal, triangular and rectangular signals.
- The software includes built-in function of verification of oscillograph channels. It also provides for profiling function.
Technical characteristics of the stand:
Power supply | USB | |
Power consumption, Watt | less than 5 | |
Stand overall dimensions: | ||
Width, mm | 180 | |
Height, mm | 200 | |
Depth, mm | 80 | |
Weight, kg | less than 1 |
Number of galvanically isolated ADC | 3 pieces | |
Number of channels in one ADC | 7 pieces | |
Frequency of ADC digitization | 1 MHz | |
The number of DAC channels | 1 pieces | |
Grid swing of DAC, up to | ±5V | |
Frequency of DAC digitization | 1 MHz | |
Range of measured voltages | ||
from | ±0.1V | |
up to | ±750V | |
Range of measured currents | ||
from | ±500μA | |
up to | ±10A | |
Accuracy rating, up to | 0.5% |
Technical characteristics of the measuring channel of ADC:
Range of voltage measurement (by amplitude)* | ±400 V (2pcs) ±50 V (3pcs) |
Range of current measurement (by amplitude)* | ±5 А (1pc) ±1 А (1pc) |
Allowable excess of measured signal amplitude | 40% |
Resolution | 12 bit |
Input sensitivity | 4·"Measurement range "÷212 |
Measurement error | ±2·"Measurement range "÷212 |
Sampling frequency | from 30 Hz to 1 mHz |
Frequency measurement range | from 0 to 60 kHz |
Input impedance | 1 MΩ |
Input capacity | 30 pF |
Number of channels DAC (ports) | 1pc |
Signal amplitude | ±5 V |
Sampling frequency | 1 MHz |
Characteristics of the software:
Timebase |
from 0,03·10-3 |
Synchronization |
by level, |
Amplitude rescaling |
from 4/1 |
Inversion |
+ |
Split capacitor |
+ |
Measurement of signal parameters |
effective value, |
Interpolation |
Linear |
Markers |
for amplitude |
Size of internal frame buffer |
from 2,36 |
Markers |
+ |
Spectrum analyzer |
+ |
Phase portrait |
+ |
Calculated channels |
+ |
Profiling functions |
+ |
Complete set of complex NTC-05.16 "Measuring complex":
- NTC-05.16 "Measuring complex";
- software;
- manual;
- passport;
- personal computer.